AC Chargers
S/N | Parameter | AC Type-2 | Technical Offered |
1 | Input voltage (VAC) | 1-Ph 230V or 3-Ph 400V (+/- 10%) | 1-Ph 230V or 3-Ph 400V (+/- 10%) |
2 | Efficiency (%) | 99.9%"}”>>99.9% | |
3 | Input Frequency (Hz) | 50Hz | 1 |
4 | Wires | 3 wire (L,N,PE) or 5 wire (L1,L2,L3,N,PE) | 1 |
5 | Number of Outputs | 1 | 1 |
6 | Output Connector Typr | IEC 62196 TYPE-2 AC | IEC 62196 TYPE-2 AC |
7 | Output Voltage (V) | 1-Ph 230V or 3-Ph 400V AC | 1-Ph 230V or 3-Ph 400V AC |
8 | Max. Output Current (A AC/DC) | Max. 62A AC | Max. 62A AC |
9 | Max. Output Power Rating (KW) | 7kW, 11kW, 22kW, 43kW AC | 7kW, 11kW, 22kW, 43kW AC |
10 | Display | 4.3″ TFT Color Touch Screen | 4.3″ TFT Color Touch Screen |
11 | Emergency Push Button | Provided | Provided |
12 | User Authentication | RFID based | RFID based / API based |
13 | Visual Indication | LCD and LED for Power, Charge and Fault | LCD and LED for Power, Charge and Fault |
14 | Charging Mode | IEC 61851-1 | IEC 61851-1 |
15 | Charger and Vehicle Communication | As per IEC 61851-1 | As per IEC 61851-1 |
16 | Charger & CMS communication | Open Charge point protocol 1.6J | Open Charge point protocol 1.6J (Optional) |
17 | Charger Interface | Ethernet, 3G/4G, Wifi | Ethernet, 3G/4G, Wifi |
18 | Protections | Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, Reverse Battery Connection | Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, |
19 | Ambient Temperature | -20 to +50C | -20 to +55C |
20 | Place of Installation | Indoor and Outdoor | Indoor and Outdoor |
21 | Ingress Protection | IP54 | IP54 |
22 | Enclosure Protection | – | – |
23 | Cooling | Natural Convection | Natural Convection |
24 | Charging Wire Length | 5 mtr | 5 mtr |
25 | Max Dimension (WxDxH)mm | 760 x 600x 1620 | 500 x 400x 600 |
26 | Max. Weight (kGs) | 75 kGs | 70 KGs |
S/N | Parameter | BHARAT AC001 | Technical Offered |
1 | Input voltage (VAC) | 3-Ph 415V (375-440 Vac) as per IS 12360 | 3-Ph 415V (370-445 Vac) as per IS 12360 |
2 | Efficiency (%) | 99.9%"}”>>99.9% | |
3 | Input Frequency (Hz) | 50Hz | 50Hz |
4 | Wires | 5 wire (L1,L2,L3,N,PE) | 5 wire (L1,L2,L3,N,PE) |
5 | Number of Outputs | 3 | 3 |
6 | Output Connector Typr | IEC 60309 | IEC 60309 |
7 | Output Voltage (V) | 1-Ph 230V AC | 1-Ph 230V AC |
8 | Max. Output Current (A AC/DC) | Max. 15A AC | Max. 16A AC |
9 | Max. Output Power Rating (KW) | 9.9kW AC (3.3kW for each Gun) | 9.9kW AC (3.3kW for each Gun) |
10 | Display | 3.5″ Inch Color Touch Screen | 3.5″ Inch Color Touch Screen |
11 | Emergency Push Button | Provided | Provided |
12 | User Authentication | RFID based | RFID based / API based |
13 | Visual Indication | LCD and LED for Power, Charge and Fault | LCD and LED for Power, Charge and Fault |
14 | Charging Mode | – | – |
15 | Charger and Vehicle Communication | – | – |
16 | Charger & CMS communication | Open Charge point protocol 1.6J | Open Charge point protocol 1.6J ( Optional) |
17 | Charger Interface | Ethernet, 3G/4G, Wifi | Ethernet, 3G/4G, Wifi |
18 | Protections | Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, Reverse Battery Connection | Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, |
19 | Ambient Temperature | -20 to +50C | -20 to +50C |
20 | Place of Installation | Indoor and Outdoor | Indoor and Outdoor |
21 | Ingress Protection | IP54 | IP54 |
22 | Enclosure Protection | IK10 | IK10 |
23 | Cooling | Natural Convection | Natural Convection |
24 | Charging Wire Length | 5 mtr | 5 mtr |
25 | Max Dimension (WxDxH)mm | 283 x 185 x 400 | 300x 185 x 400 |
26 | Max. Weight (kGs) | 7 kGs | 8.2 kGs |