S/N |
Parameter |
DC CCS-2 |
Technical Offered |
1 |
Input voltage (VAC) |
3-Ph 400V (+/- 10%) |
3-Ph 400V (+/- 10%) |
2 |
Efficiency (%) |
>=94% |
>=94.5% |
3 |
Input Frequency (Hz) |
45-65 Hz |
45-65 Hz |
4 |
Wires |
5 wire (L1,L2,L3,N,PE) |
5 wire (L1,L2,L3,N,PE) |
5 |
Number of Outputs |
1 |
1 |
6 |
Output Connector Typr |
IEC 62196-3 |
IEC 62196-3 |
7 |
Output Voltage (V) |
100-750V DC |
100-750V DC |
8 |
Max. Output Current (A AC/DC) |
Max. 80A DC |
Max. 80A DC |
9 |
Max. Output Power Rating (KW) |
Max. 30kW DC |
Max. 30kW DC |
10 |
Display |
4.3″ TFT Color Touch Screen |
4.3″ TFT Color Touch Screen |
11 |
Emergency Push Button |
Provided |
Provided |
12 |
User Authentication |
RFID based |
RFID based / API based |
13 |
Visual Indication |
LCD and LED for Power, Charge and Fault |
LCD and LED for Power, Charge and Fault |
14 |
Charging Mode |
IEC 61851-1 (Mode-4) |
IEC 61851-1 (Mode-4) |
15 |
Charger and Vehicle Communication |
Power line Communication (PLC) |
Power line Communication (PLC) |
16 |
Charger & CMS communication |
Open Charge point protocol 1.6J |
Open Charge point protocol 1.6J |
17 |
Charger Interface |
Ethernet, 3G/4G, Wifi |
Ethernet, 3G/4G, Wifi |
18 |
Protections |
Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, Reverse Battery Connection |
Input Over voltage, Input Under Voltage, Connection Abnormality, Emergency Stop, Lightning Protection, Leakage, Short Circuit, Over current, Over temperature, Reverse Battery Connection |
19 |
Ambient Temperature |
-20 to +50C |
-20 to +50C |
20 |
Place of Installation |
Indoor and Outdoor |
Indoor and Outdoor |
21 |
Ingress Protection |
IP54 |
IP54 |
22 |
Enclosure Protection |
IK10 |
IK10 |
23 |
Cooling |
Natural Convection |
Natural Convection / Forced cooling in the Power modules |
24 |
Charging Wire Length |
5 mtr |
5 mtr |
25 |
Max Dimension (WxDxH)mm |
530 x 270 x 752 |
900 X 720 X 1600 |
26 |
Max. Weight (kGs) |
68 kGs |
75 KGs |